Operating Mode:
P1: trigger signal, the relay is on "OP" time, and then disconnect; in the "OP" time, as follows:
P1.1: signal is triggered again, invalid
P1.2: signal is triggered again, the clocking is reset
P1.3: Signal is trigger again reset, relay off, and stop the clocking;
P-2: trigger signal, the relay off "CL" of time, the relay on "OP" time, and then disconnect relay after clocking;
P3.1: trigger signal, the relay is turned on after the "OP" time, the relay off "CL" time, then the operation cycles; if trigger signal again during the cycle, the relay off, stop clocking; the number of cycles times ( "LOP ") can be set.
P3.2: without triggering signal after power on, the relay is on "OP" time, the relay off "CL" time, then the operation cycles; the number of cycles times ( "LOP ") can be set.
P-4: signal holding function. If there is trigger signal, clocking is reset, the relay remains on; when the signal disappears, after clocking "OP" time, the relay is off; if another signal is triggered during clocking, clocking will be reset.
How to Set Clocking Range:
After setting the parameter value at mode selection, press "STOP" button to set the clocking range;
XXX. The last decimal point lights up, range: 1 second to 999 seconds.
XX. X The second last decimal point lights up, range: 0.1 seconds to 99.9 seconds
X. X. X. all 3 decimal points light up, range: 1 minute to 999 minutes.
For example, if you want to set "OP" as 3.2 seconds, light up the second last decimal point, and set digit display as 03.2.
• Dual-MOS in parallel active output, lower inner resistance, larger current, strong power; at room temperature, operating current is up to 15A, power up to 400W, that can be used for most equipment
• Wide voltage input from 5V to 36V, normally used for controlling DC motors, lights, LED strips, micro-pumps, solenoid valves, etc.High voltage level trigger (3.0V~24V), signal ground and system ground are not on common ground to improve the system's anti-jamming capability (you can also connect them on common ground)
• 0.1 seconds (min) to 999 minutes (max) continuously adjustable.To achieve fast high frequency turn-on and off circuit, an unlimited number of switching times.No noise was made during turning on/off, no spark, and no electromagnetic interference
• The emergency stop function (“STOP” key);With reverse polarity protection, reverse polarity will not burn the product.Increase the sleep mode, if this mode is enabled, without any operation within 5 minutes, then automatically turn off the monitor, any key wake-up;You can set a different OP, CL, LOP parameters, which are independent of each other, and are automatically saved;After the module is powered down, all parameter settings are not lost
• Note:The module is an active output, the output voltage equal to the input voltage.'DC + 'and' load + 'This is an internal short circuit of the poles, but' DC- 'and' load - 'poles during use can not be shorted, otherwise the load can not be controlled on and off, which is equivalent load is been carrying electricity