
Time Delay Relay, CavalliFun Timer Delay Controller Module DC 5V 12V 24V, Delay Power-Off Trigger, LCD Display Delay-Off Cycle Timer 0.01s-9999mins and Delay Switch Control Support Micro USB 5V Input
Amazon Price as of 06/09/2025 21:02 GMT+00:00
$4.99
Deal Detector and Price History
We analyze price history to spot good deals

Include Prime Price
🎉 Great Deal
average price $12.99
$8 cheaper than average
$8.74
$16.24
Product Description
Parameters: 1. Timing Range: 0.1 Seconds to 999 Minutes 2. Working Voltage: DC5V-30V, support Micro USB5.0V power supply 3. Trigger Type: Button/PNP/NPN/High/Low Level Signal 4. Static Current: 20mA 5. Working Current: 50mA 6. Load(Max): DC 30V 10A or AC 250V 10A 7. Life Life: greater than 100,000 times 8. Work Temperature: -40 ~ 85 ℃ Special Attention: relay output is a passive contact, without charging output, controlling a line interrupting effect. Parameter Description: OP: Delay time for turn On; CL: Delay time for turn OFF; LOP: Number of cycles.Range is 1-999tims. ’----’ means unlimited loop. CLL: Minimum value of random delay time range. The setting range is 0.0~99.9second. This CLL parameter is used for P15 work mode. CLH: Maximum value of random delay time range.The setting range is 0.0~99.9second. This CLH parameter is used for P15 work mode. CLH value is greater than CLL value. Parameter Setting Method: 1.First determine the working mode of the module; 2.According to the working mode of the module, in the main interface (when the module is powered on, it will flash the current working mode (default P01 mode), and then enter the main interface,) "long press the SET button for 2 seconds and release it" to enter On the mode selection interface, short press the UP and DOWN buttons to select the mode to be set (P00~P15); 3.After selecting the mode (such as P03), short press the SET button to set the corresponding parameters, then the parameters will flash (OP on time, CL off time, LOP cycle times ("---" Represents infinite loops)), adjust the parameter value through UP and DOWN, support long press (fast increase or decrease) and short press (increase or decrease 1 unit); 4.After setting the parameter value, short press the STOP button to select the decimal point position and select the timing range (the corresponding time is 0.1 seconds to 999 minutes); short press the SET button to set the next parameter of the current mode, the process is the same as above; 5.P15 mode: After selecting the mode, short press the SET button to set the corresponding parameters, then the parameters will flash (CLL disconnection time lower limit, CLH disconnection time upper limit), adjust the parameters through UP and DOWN value. Support long press (fast increase or decrease) and short press (increase or decrease 1 unit), timing range (corresponding time 0.1 seconds ~ 99.9 seconds); short press the SET button to set the next parameter of the current mode, the process is the same as above ; 6.After setting the parameters of the selected mode, press and hold the SET button for 2 seconds and then release, the currently set mode will flash, and then return to the main interface, the parameters are successfully set. STOP Button Function Extension: Module enable mode: 1.ON: OP During the module allows the module to be turned on; 2.OFF: Module prohibits diverting, always closing the state; Press the STOP button in the main interface to implement the switch between ON and OFF. The current state will flash, and then return to the main interface. (This function is an emergency stop function. Sleep mode: 1.CL sleep mode: Within three minutes, no operation, the digital tube automatically close the display, the program normal operation; 2.O-D normal mode: The digital tube is always opened and displayed; Press the Stop button for 2 seconds and loosen it after 2 seconds to achieve the switching of the C-L and O-D state. The current state will flash, and then return to the main interface.
Reviews
Review AI Summary